The Kleihauer Test

The Kleihauer test (KT) is the reference biological test for detecting, quantifying, and monitoring FMH. It is a simple microscopic technique based on the differentiation of fetal red blood cells from maternal red blood cells. KBT enables early and reliable diagnosis of FMH, supporting optimized management of both patients and newborns.

FMH is defined as the passage of fetal red blood cells into the maternal bloodstream. This passage may be spontaneous or observed during childbirth, abdominal trauma or particular obstetric contexts. If FMH is not detected, it can have potentially serious consequences for the foetus and expose the mother to the risk of foeto-maternal alloimmunisation.

In France, the KT is the test most frequently prescribed by practitioners in the context of a high risk of FMH and as part of the prevention of Rhesus D alloimmunisation in order to adapt the dosage of anti-RH1 immunoglobulins.

KT has often been criticised for its lack of reproducibility. In order to reduce the variability of KT, IBJB offers a staining kit that has been validated and complies with regulatory requirements, compatible with manual assisted or semi-automated use with the Easy-K or automated use with the K-Matic.

Reference method :

The Kleihauer test is a cytochemical blood smear test based on the acid resistance of fetal haemoglobin. After acid elution and double staining, fetal red blood cells can be identified and quantified in maternal blood.

Detection of fetal-maternal haemorrhage (FMH) :

Used to assess the amount of fetal blood passing into the maternal circulation and adapt the dose of anti-D immunoglobulin to prevent alloimmunisation in RhD-negative patients (RH: -1).

Validated technique :

Used for several decades, it remains the reference laboratory technique thanks to its simplicity and speed of execution.

Performances :

Our technique is highly sensitive, with a detection threshold of 1 fetal red blood cell per 10,000 adult red blood cells.

These devices comply with regulatory requirements, meeting Directive 98/79/EC, and are in the process of being CE-IVD marked in accordance with Regulation (EU) 2017/746, guaranteeing the safety and performance of the devices.

Safety and optimised management

  • The use of positive and negative control slides avoids false negatives.
  • Optimised use of reagents: Stable solutions and reagents can be used for several series of tests with optimum storage.
  • Can be coupled with IQC (Internal Quality Controls) such as IJB K-Control, ensuring continuous verification of the analytical process.
Access the product data sheet

Suitable reagent kits

The kits allow 30-slide tests, including reagent bottles and positive and negative control slides. 3 kit references are available, depending on the technique and the number of slides to be stained daily :

Identification :

K-Matic kit 5 vials :

Reference : 901080133

K-Matic set of 5 vials for use in automated systems

  • Staining of at least 15 slides per day
  • Ready-to-use case including 2 vials of elution solutions
  • Use with K-Matic

Identification :

K-Matic kit 8 vials:

Reference : 901080134

K-Matic set of 8 vials for use in automated systems

  • Staining up to 14 slides per day
  • Ready-to-use case including 5 vials of elution solutions
  • Use with K-Matic

Identification :

Easy-K kit 8 vials :

Reference : 901080234

Easy-K set of 8 vials for optimised manual use.

  • Staining up to 14 slides per day
  • Ready-to-use case including 5 vials of elution solutions
  • Use with Easy-K

Compatibility with different application techniques

Optimised manual version with Easy-K

Optimised manual version with Easy-K

Discover our manual version with the Easy-K

Automated version with K-Matic

Automated version with K-Matic

Discover our optimized version with K-Matic.

Support and guidance

  • Manufacturer’s warrantly : Guaranteed analyses thanks to products that have been tested and validated under real-life conditions.
  • Dedicated technical assistance : Support for laboratories in integrating and using the test

 

Contact us!

Why choose IBJB Kleihauer kits ?

An approved and validated technique for the quantification of FMH.

A test that complies with European regulations and is easy to integrate into the laboratory.

A flexible solution, available in manual or automated versions.

Dedicated support and additional tools for maximum reliability.

Recommended accessories :

Discover the IBJB accessories recommended for use with Kleihauer kits.

Access to full product details

icone fiche Storage
conditions
icone fiche Compatible
accessories
icone fiche Technical
Features
icone fiche Methods
of use

Need advice or a tailor-made solution?

Our team of experts is available to discuss your projects and answer your questions.

Contacts
  • Pôle Technologique Henri Farman
    4 Allée Albert Caquot
    51100 Reims, FRANCE
  • contact@ibjb.fr
  • phone : +33 (0)3 26 79 72 72
  • fax : +33 (0)3 26 79 72 73