Collagen Type I Rat TailA natural substrate that promotes cell adhesion, growth and differentiation under in vitro conditions.
Red blood cell washing and preservation solutions
Research Use Only (RUO)
Our RUO solutions :
RUO (“Research Use Only”) products are used solely for research purposes and are not intended to be used for diagnostic purposes.
RUO products include reagents, equipment and specialised materials essential for scientific investigations, making a significant contribution to the development of cutting-edge tools and solutions for research applications.
BFI solution (LISS solution) :
BFI solution (LISS solution) :
Reference : 105010465 (for 500 ml).Additional information :
- Description – LISS (Low Ionic Strength Solution) is a variant of Low and Messeter’s low ionic strength saline solution, used in various immunohematology techniques.
- Typical RUO application – The use of LISS solution as a suspension medium for red blood cells in the indirect antiglobulin test increases the sensitivity of the reaction, facilitates the accessibility of blood antigens and increases the speed of antibody binding, thereby reducing incubation times compared with saline techniques.
[1] LOW B., MESSETER L., Antiglobulin Test in Low-Ionic Strength Salt Solution for rapid Antibody Screening and Cross-Matching, Vox. Sang.,26 , 53-61 (1974).
[2] MOORE C., MOLLISON P.L., Use of a Low-Ionic-Strength Medium in Manual Tests for Antibody Detection, Transfusion,16 , 291-296 (1976).
Solution 738 NaCl 9g/L buffered :
Solution 738 NaCl 9g/L buffered
Reference : 105010468 (for 500 ml), 105010467 (for 5000 ml).Additional information :
- Description – Solution 738 is a buffered 0.9% (w/v) sodium chloride (NaCl) solution with a pH of between 7.6 and 7.9.
- Typical RUO application – This saline solution has an osmolarity of 300±60 mOsm/L, so it is isotonic with blood and major human body fluids and provides an environment that maintains the physiological integrity of most mammalian cells in vitro.
Solution 548 (red blood cells freezing)
Solution 548 (red blood cells freezing)
Reference : 105010754 (for 100 ml).Additional information :
- Description – Solution 548 is a ready-to-use, chemically defined red blood cell freezing medium with a high glycerol content (40% w/v) and no components of human or bovine origin.
- Typical RUO application – Glycerol has been the most commonly used cryoprotectant for red blood cell cryopreservation since the 1950s. It modulates the transport of water in cell membranes and inhibits the formation of intracellular ice responsible for red blood cell hemolysis, in order to maintain good red blood cell viability after thawing. At high concentrations, glycerol enables red blood cells to be stored at a temperature of between -65°C and -80°C, for up to 10 years.
[1] SMITH A.U., Prevention of haemolysys in frozen blood, The Lancet., 2, 910-911 (1950).
[2] ROGERS S.C., DOSIER L.B., MAC MAHON T.J., ZHU H. and coll., Red blood cell phenotype fidelity following glycerol cryopreservation optimized for research purposes, PLOS one,13, 1-21(2018).
[3] LAGERBERG J.W., Cryopreservation of red blood Cells, Methods Mol. Biol.,1257, 353-367(2015).
Solution 533 (washing / thawing of red blood cells) :
Solution 533 (washing / thawing of red blood cells)
Reference : 105010568 (for 500 ml).Additional information :
- Description – Solution 533 is a chemically defined, ready-to-use medium without components of human or bovine origin, used in the process of freezing and thawing red blood cells.
- Typical RUO application – Specifically formulated with hypertonic sorbitol solutions and isotonic sodium chloride solutions in order to facilitate the long-term conservation of red blood cells without altering the erythrocyte antigens during the freezing stage, thus allowing rare and varied phenotypes to be available at any time. It also minimizes hemolysis when the glycerol is removed after thawing.
[1] SMITH A.U., Prevention of haemolysys in frozen blood, The lancet.,2,910-911 (1950).
[2] ROGERS S.C., DOSIER L.B., MAC MAHON T.J., ZHU H. and coll., Red blood cell phenotype fidelity following glycerol cryopreservation optimized for research purposes, PLOS one,13, 1-21(2018).
[3] LAGERBERG J.W., Cryopreservation of red blood Cells, Methods Mol. Biol.,1257, 353-367(2015).
[4] COMBRISSON A. et coll., Conservation des hématies par congélation en présence de glycérol et sorbitol, Revue française de transfusion,11, 7-22(1968).
Solution 534 (thawing of red blood cells)
Solution 534 (thawing of red blood cells)
Reference : 105010668 (for 500 ml)Additional information:
- Description – Solution 534 is a chemically defined, ready-to-use medium without components of human or bovine origin, used specifically in the process of thawing red blood cells.
- Typical RUO application – Solution 534 has been specifically formulated with hypertonic sorbitol and isotonic sodium chloride solutions to minimize hemolysis when glycerol is removed after thawing.
[1] SMITH A.U., Prevention of haemolysys in frozen blood, The lancet.,2,910-911 (1950).
[2] ROGERS S.C., DOSIER L.B., MAC MAHON T.J., ZHU H. and coll., Red blood cell phenotype fidelity following glycerol cryopreservation optimized for research purposes, PLOS one,13, 1-21 (2018).
[3] LAGERBERG J.W., Cryopreservation of red blood Cells, Methods Mol. Biol.,1257, 353-367(2015).
[4] COMBRISSON A. et coll., Conservation des hématies par congélation en présence de glycérol et sorbitol, Revue française de transfusion,11, 7-22(1968).
Use and Compliance of Red Blood Cell washing and preservation solutions (RUO)
These solutions are strictly reserved for use in research laboratories and must under no circumstances be used for diagnostic, therapeutic or clinical applications in humans.
Full documentation from the supplier is expected, specifying the composition, storage and recommended applications of RUO products, manufactured in accordance with the current ISO 13485 standards, even though they are not subject to IVD requirements.
As with any laboratory reagent, it is recommended that these solutions are handled in accordance with good laboratory practice, including the wearing of appropriate personal protective equipment.
Access to full product details
conditions
accessories
Features
of use
Need advice or a tailor-made solution?
Our team of experts is available to discuss your projects and answer your questions.
- Pôle Technologique Henri Farman
4 Allée Albert Caquot
51100 Reims, FRANCE - contact@ibjb.fr
- phone : +33 (0)3 26 79 72 72
- fax : +33 (0)3 26 79 72 73